CCC Cable Coupling Clamp
The Cable Coupling Clamp (CCC01) is a reusable聽test jig for the purpose of measuring the shielding聽properties of cables.
The CCC01 is designed to聽allow easy positioning of the test and injection feed聽cables in accordance with the layout described in聽IEC 96-1 Amendment 2 1993-06. This simplifies聽the process of making repeatable measurements聽aimed at assessing the coupling and shielding聽effectiveness properties of a wide range of cables.
The CCC01 design is based on the details of the 鈥渓auncher鈥澛燼rrangement, described in IEC 96-1 Amendment 2 1993-06聽section A.5.6 Line Injection Method (frequency domain).聽This arrangement is also used in IEC 62153-4-6: 2006 and聽mandated for the line injection method in EN 50289-1-6.
Key Features
- Fixed cable routes
- Cable injection assemblies
- Supports a range of test cable sizes
- 0.3 m & 0.5 m test lengths
- Configurable injection conductor
- Easy connection to test system
Features/Applications
Features
- Fixed cable Routes; repeatable layout of test and injection cables
- Cable injection assemblies; injection cable runs are supplied pre-assembled and fitted with聽ferrite common mode chokes
- Supports a range of test cable sizes; 2.5 mm, 5 mm and 10 mm aperture supports provided as聽standard.聽Cable dimensions up to 22 mm x 13 mm are possible聽with the user-machinable fitting accessories
- 0.3 m & 0.5 m test lengths; base plate allows the injection assemblies to be mounted either聽for a 0.3m cable length (EN 50289-1-6) or the extended聽0.5 m length聽 (IEC 96-1) for increased coupling distance
- Configurable injection conductor; self-adhesive copper tape, easily trimmed to the correct width聽required according to the circumference of the cable under test
- Easy Connection to test system; injection cables are terminated in N-type connectors
Applications
- Cable shielding effectiveness measurements as indicated by
- IEC 96-1 Amendment 2 1993-06
- IEC 62153-4-6:2006
- EN 50289-1-6
- Investigation of cable coupling phenomena
Specifications
Frequency Range
- 10 kHz to 1 GHz typical (usable to higher frequencies, depending on the cables聽being tested and application of the test)
Output connectors
- 50 惟 N-type sockets
Cable Sizes
- Approx. 2.5 mm to 10 mm diameter using the three sets of fittings supplied.
- User-machinable fittings available as accessories, supporting maximum of聽cable聽dimension of 22 mm x 13 mm (rectangular cross-section) or a 13 mm diameter
Time Stability
- Typically <1 dB over a 12 month period
Dimensions
- 220 mm 脳 880 mm (0.5 m test setting)
- 220mm 脳 740mm (0.3m test setting)
Weight
- 3 kg (typical excluding cable-under-test and any associated ferrites)
Kits
Standard Order Kits
CCC01KIT01 鈥 Standard CCE01 cable聽coupling clamp kit
Parts included
- Pair of pre-assembled cable injection assemblies
- Base plate with mounting positions for 0.3 m and聽0.5 m cable test lengths
- 2.5 mm, 5 mm and 10 mm diameter cable mounting fittings
- Additional clip-on ferrite chokes
- Self-adhesive copper tape (signal injection conductor)
- Hard case for injection assemblies and accessories
- Manual
Please note: We聽are unable to supply the cable under test (CUT), any parts associated with its聽construction and any ferrite rings to be fitted to it.
Accessories
CMF01 鈥 Kit of user-machinable blank fittings for custom cable apertures (single cable)
Special 鈥 聽Contact us for information regarding our testing service for cables to both IEC 96-1 and EN 50289-1-6, using the CCC01







As part of our regular yearly series of seminars, Wurth Electronics UK and 黑料社区 Electrical & Electronics UK have a series of free 1-day technical presentations and demonstrations planned in 2026.